0

Series Partial Discharge-free Power Supply

Waveform Purity: Low harmonic distortion

Overload Robust: Modular design, impact resistant, zero voltage drop

Fast Dynamic Response: Small voltage drop, fast recovery

Intuitive Operation: LCD touchscreen

Stable Frequency: Quartz oscillator, high precision

Strong Anti-interference: Fiber optic drive, high reliability

Comprehensive Protection: Electrostatic powder coating, conformal coating +

Sales Count Click

Sales Count

Click

Series Partial Discharge-free Power Supply

Select the number of specifications

Please check the product information you want!

Product Detail

 
Overview:
 

The WF60 series partial discharge-free power supply utilizes an excitation transformer to energize a series or parallel resonant circuit. By adjusting the output frequency of the power supply, the inductor and capacitor in the circuit resonate, and the resonant voltage is the voltage applied to the test specimen. Alternatively, it can directly output through an intermediate transformer to the primary winding of the transformer for induced voltage withstand testing. It is suitable for AC voltage withstand tests and partial discharge tests of all electrical equipment.

 

Features:
Dielectric Loss-Free Power Supply

Excellent output waveform: Low voltage harmonic distortion rate and low harmonic content.Strong overload capacity: The power unit is modular and can withstand the surge current of the motor without causing a voltage drop.

Fast dynamic response: Small transient voltage changes under sudden load changes, and fast recovery time.Intuitive display and easy operation:  It uses an LCD touch screen with both Chinese and English language options.

Excellent stability: High frequency stability, generated by a quartz oscillator, resulting in a very stable and precise frequency.

Strong anti-interference capability:  Utilizing fiber optic drive control, it possesses extremely strong resistance to electromagnetic interference and high reliability.

High protection level: The equipment cabinet surface is treated with electrostatic powder coating, and the PCBs are treated with conformal coating and potting compound.

 

Circuit Block Diagram:

 

Dielectric Loss-Free Power Supply

 

Application industries:

 

This equipment is used for AC withstand voltage and partial discharge testing in applications such as transformers, circuit breakers, switches, GIS systems, cables, bushings, and insulating terminals.

 

Product Applications:

Dielectric Loss-Free Power Supply

 

External Dimensions:

 

 

Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-31100400 650 800 
WF60-31150400 650 800 
WF60-31200500 820 1100 
WF60-31300500 820 1100 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-31450520 1160 1360 
WF60-31600520 1160 1360 
WF60-311000650 1420 1470 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-3120001900 1100 1970 
WF60-3130001900 1100 1970 
WF60-3140001900 1100 1970 

 

Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-33100500 820 1100 
WF60-33200500 820 1100 
WF60-33300520 1160 1360 
WF60-33450520 1160 1360 
WF60-33600650 1420 1470 
WF60-33900650 1420 1470 
WF60-331000650 1420 1470 
WF60-331200650 1420 1470 
WF60-331500650 1420 1470 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-3320001550 850 1985 
WF60-3330001550 850 1985 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-3340001900 1100 1970 

 

 

Technical Parameters:
 
Unit TypeWF60-31100WF60-31150WF60-31200WF60-31300WF60-31450
Rated Power10kVA15kVA20kVA30kVA45kVA
Input AC Indicators    
Power Supply FormatThree-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply Format Single-phase two-wire + PE (protective earth)
Voltage Range 0~800VL-N( Standard configuration/0~1000VL-NOptional features
Current Range 12A18A25A37A60A
Frequency Range Fixed frequency: 50/60Hz, Variable frequency: 30~300Hz
Source Effect ≤ 0.1%F.S
Load Effect ≤ 0.1%F.S
Voltage Accuracy ≤ 0.1%F.S
Frequency Accuracy ≤ 0.01%F.S
Voltage Harmonic ≤ 2%
Response Time ≤ 5ms
Partial Discharge
Quantity
 20 pC (standard) / 10 pC (optional) / 5 pC (optional)
Device Efficiency ≥ 90%
Overload Capacity 120%-150%, 1 minute; 150%-200%, 2 seconds; 200%, immediate output shutdown.
System Function  
Memory FunctionAfter a power outage and subsequent power restoration, the device can remember the last output mode and parameters.
Protection FunctionInput undervoltage/overvoltage and phase loss protection, output overvoltage, overcurrent, overload, and short-circuit prot
ection, and internal overtemperature protection, etc.
Display and Communication
Local Operation LCD display screen
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote Communication    RS 485/LAN
Communication
Protocol
 Standard Modbus RTU/Modbus TCP/IP
Safety Performance 
Compressive Strength 2000 Vdc / 60 seconds / No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling MethodFan-forced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Power Supply
(W*D*Hmm
400*650*800
(With wheels)
400*650*800
(With wheels)
500*820*1100
(With wheels)
500*820*1100
(With wheels)
    520*1160*1360
      (With wheels)
FilterW*D*Hmm600*400*162600*400*162600*400*162600*400*1621000*572*162

 

Unit Type

WF60-31600WF60-311000WF60-312000WF60-313000WF60-314000
Rated Power60kVA100kVA200kVA300kVA400kVA
Input AC Indicators     
Power Supply FormatThree-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply Format Single-phase two-wire
Voltage Range 0~800VL-N( Standard configuration)/0~1000VL-NOptional features
Current Range 75A125A250A375A500A
Frequency Range Fixed frequency: 50/60Hz, Variable frequency: 30~300Hz
Source Effect ≤ 0.1%F.S
Load Effect ≤ 0.1%F.S
Voltage Accuracy ≤ 0.1%F.S
Frequency Accuracy ≤ 0.01%F.S
Voltage Harmonic ≤ 2%
Response Time ≤ 5ms
Partial Discharge
Quantity
 ≤ 20pC( Standard configuration≤ 10pCOptional features≤ 5pCOptional features
Device Efficiency ≥ 90%
Overload Capacity 120%-150%, 1 minute; 150%-200%, 2 seconds; 200%, immediate output shutdown.
System Function  
Online Adjustment
Function
Output voltage and frequency can be adjusted online.
Quick Settings
Function
Multiple output voltages and frequencies can be customized.
Memory FunctionAfter a power outage and subsequent power restoration, the device can remember the last output mode and parameters.
Protection FunctionInput undervoltage/overvoltage and phase loss protection, output overvoltage, overcurrent, overload, and short-circuit protection, and
internal overtemperature protection, etc.
Display and Communication
Local Operation LCD display screen
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote Communication RS 485/LAN
Communication protocol Standard Modbus RTU/Modbus TCP/IP
Safety Performance  
Compressive Strength 2000 Vdc / 60 seconds / No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment  
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling MethodFan-forced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000m Reduced usage
Power supply
(W*D*H)mm
520*1160*1360
(With wheels)
650*1420*1470
(With wheels)
1550*850*1985
(With wheels)
1550*850*1985
(With wheels)
1900*1100*1970
FilterW*D*H
mm
1000*572*1621000*572*1621300*700*2601300*700*2601300*700*260

 

    800*500*162      800*500*162

Unit TypeWF60-33100WF60-33200WF60-33300WF60-33450WF60-33600WF60-33900
Rated Power10kVA20kVA30kVA45kVA60kVA90kVA
Input AC Indicators     
Power Supply FormatThree-phase four-wire + PE (protective earth)
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply FormatThree-phase four-wire
Voltage Range0~800VL-L( Standard configuration/0~1000VL-L(Optional features
Current Range7A14A21A32A42A63A
Frequency RangeFixed frequency: 50/60Hz, Variable frequency: 30~300Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonic≤ 2%
Response Time≤ 5ms
Partial Discharge
Quantity
20 pC (standard) / 10 pC (optional) / 5 pC (optional)
Device Efficiency≥ 90%
Overload Capacity     120%–150%, 1 minute; 150%–200%, 2 seconds; 200%, immediate output shutdown.
System Function 
Online Adjustment
Function
Output voltage and frequency can be adjusted online.
Quick Settings
Function
Multiple output voltages and frequencies can be customized.
Memory Function    After a power outage and subsequent power restoration, the device can remember the last output mode and parameters.
Protection FunctionInput undervoltage/overvoltage and phase loss protection, output overvoltage, overcurrent, overload, and short-circuit
protection, and internal overtemperature protection, etc.
Display and Communication
Local Operation LCD display screen
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote Communication RS 485/LAN
Communication protocol Standard Modbus RTU/Modbus TCP/IP
Safety Performance
Compressive Strength 2000 Vdc / 60 seconds / No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling MethodFan-forced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Power supply
(W*D*H)mm
500*820*1100
(With wheels)
500*820*1100
    (With wheels)
     520*1160*1360
       (With wheels)
520*1160*1360
(With wheels)
650*1420*1470
(With wheels)
650*1420*1470
(With wheels)
FilterW*D*H
mm
800*500*162800*500*1621000*600*1621000*600*162

 

Unit TypeWF60-331000WF60-331200WF60-331500WF60-332000WF60-333000WF60-334000
Rated Power100kVA120kVA150kVA200kVA300kVA400kVA
Input AC Indicators      
Power Supply FormatThree-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply Format Three-phase four-wire
Voltage Range 0~800VL-L( Standard configuration)/0~1000VL-LOptional features
Current Range      72A86A108A144A216A288A
Frequency Range Fixed frequency: 50/60Hz, Variable frequency: 30~300Hz
Source Effect ≤ 0.1%F.S
Load Effect ≤ 0.1%F.S
Voltage Accuracy ≤ 0.1%F.S
Frequency Accuracy ≤ 0.01%F.S
Voltage Harmonic ≤ 2%
Response Time ≤ 5ms
Partial Discharge
Quantity
 ≤ 20pC(Standard configuration)/ ≤ 10pC(Optional features)/ ≤ 5pC(Optional features
Device Efficiency ≥ 90%
Overload Capacity 120%~150% , 1min; 150%~200% 2s ;≥ 200% , Immediately shut off the output.
System Function  
Online Adjustment
Function
Output voltage and frequency can be adjusted online.
Quick Settings
Function
Multiple output voltages and frequencies can be customized.
Memory FunctionAfter a power outage and subsequent restoration, the device can remember the last output mode and parameters.
Protection Function   Input undervoltage and overvoltage protection, phase loss protection; output overvoltage, overcurrent, overload, and short-circuit
   protection; internal overtemperature protection, etc.
Display and Communication
Local Operation LCD display
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S., Current: 0.2% F.S., Frequency: 0.01%, Power: 0.3% F.S.
Remote Communication RS 485/LAN
Communication Protocol Standard Modbus RTU/Modbus TCP/IP
Safety Performance  
Compressive Strength 2000 Vdc / 60 seconds / No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment  
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures of -20℃ to 45℃ and relative humidity of 0 to 95%.
Cooling MethodFan-forced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Power supply
(W*D*H)mm
650*1420*1470
(With wheels)
650*1420*1470
(With wheels)
650*1420*1470
(With wheels)
1550*850*1985
(With wheels)
1550*850*1985
(With wheels)
1900*1100*1970
FilterW*D*H
mm
1000*600*1621000*600*1621000*600*1621300*770*2601300*770*2601300*770*260

 

No comment

Product Detail
 
Overview:
 

The WF60 series partial discharge-free power supply utilizes an excitation transformer to energize a series or parallel resonant circuit. By adjusting the output frequency of the power supply, the inductor and capacitor in the circuit resonate, and the resonant voltage is the voltage applied to the test specimen. Alternatively, it can directly output through an intermediate transformer to the primary winding of the transformer for induced voltage withstand testing. It is suitable for AC voltage withstand tests and partial discharge tests of all electrical equipment.

 

Features:
Dielectric Loss-Free Power Supply

Excellent output waveform: Low voltage harmonic distortion rate and low harmonic content.Strong overload capacity: The power unit is modular and can withstand the surge current of the motor without causing a voltage drop.

Fast dynamic response: Small transient voltage changes under sudden load changes, and fast recovery time.Intuitive display and easy operation:  It uses an LCD touch screen with both Chinese and English language options.

Excellent stability: High frequency stability, generated by a quartz oscillator, resulting in a very stable and precise frequency.

Strong anti-interference capability:  Utilizing fiber optic drive control, it possesses extremely strong resistance to electromagnetic interference and high reliability.

High protection level: The equipment cabinet surface is treated with electrostatic powder coating, and the PCBs are treated with conformal coating and potting compound.

 

Circuit Block Diagram:

 

Dielectric Loss-Free Power Supply

 

Application industries:

 

This equipment is used for AC withstand voltage and partial discharge testing in applications such as transformers, circuit breakers, switches, GIS systems, cables, bushings, and insulating terminals.

 

Product Applications:

Dielectric Loss-Free Power Supply

 

External Dimensions:

 

 

Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-31100400 650 800 
WF60-31150400 650 800 
WF60-31200500 820 1100 
WF60-31300500 820 1100 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-31450520 1160 1360 
WF60-31600520 1160 1360 
WF60-311000650 1420 1470 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-3120001900 1100 1970 
WF60-3130001900 1100 1970 
WF60-3140001900 1100 1970 

 

Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-33100500 820 1100 
WF60-33200500 820 1100 
WF60-33300520 1160 1360 
WF60-33450520 1160 1360 
WF60-33600650 1420 1470 
WF60-33900650 1420 1470 
WF60-331000650 1420 1470 
WF60-331200650 1420 1470 
WF60-331500650 1420 1470 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-3320001550 850 1985 
WF60-3330001550 850 1985 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
WF60-3340001900 1100 1970 

 

 

Technical Parameters:
 
Unit TypeWF60-31100WF60-31150WF60-31200WF60-31300WF60-31450
Rated Power10kVA15kVA20kVA30kVA45kVA
Input AC Indicators    
Power Supply FormatThree-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply Format Single-phase two-wire + PE (protective earth)
Voltage Range 0~800VL-N( Standard configuration/0~1000VL-NOptional features
Current Range 12A18A25A37A60A
Frequency Range Fixed frequency: 50/60Hz, Variable frequency: 30~300Hz
Source Effect ≤ 0.1%F.S
Load Effect ≤ 0.1%F.S
Voltage Accuracy ≤ 0.1%F.S
Frequency Accuracy ≤ 0.01%F.S
Voltage Harmonic ≤ 2%
Response Time ≤ 5ms
Partial Discharge
Quantity
 20 pC (standard) / 10 pC (optional) / 5 pC (optional)
Device Efficiency ≥ 90%
Overload Capacity 120%-150%, 1 minute; 150%-200%, 2 seconds; 200%, immediate output shutdown.
System Function  
Memory FunctionAfter a power outage and subsequent power restoration, the device can remember the last output mode and parameters.
Protection FunctionInput undervoltage/overvoltage and phase loss protection, output overvoltage, overcurrent, overload, and short-circuit prot
ection, and internal overtemperature protection, etc.
Display and Communication
Local Operation LCD display screen
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote Communication    RS 485/LAN
Communication
Protocol
 Standard Modbus RTU/Modbus TCP/IP
Safety Performance 
Compressive Strength 2000 Vdc / 60 seconds / No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling MethodFan-forced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Power Supply
(W*D*Hmm
400*650*800
(With wheels)
400*650*800
(With wheels)
500*820*1100
(With wheels)
500*820*1100
(With wheels)
    520*1160*1360
      (With wheels)
FilterW*D*Hmm600*400*162600*400*162600*400*162600*400*1621000*572*162

 

Unit Type

WF60-31600WF60-311000WF60-312000WF60-313000WF60-314000
Rated Power60kVA100kVA200kVA300kVA400kVA
Input AC Indicators     
Power Supply FormatThree-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply Format Single-phase two-wire
Voltage Range 0~800VL-N( Standard configuration)/0~1000VL-NOptional features
Current Range 75A125A250A375A500A
Frequency Range Fixed frequency: 50/60Hz, Variable frequency: 30~300Hz
Source Effect ≤ 0.1%F.S
Load Effect ≤ 0.1%F.S
Voltage Accuracy ≤ 0.1%F.S
Frequency Accuracy ≤ 0.01%F.S
Voltage Harmonic ≤ 2%
Response Time ≤ 5ms
Partial Discharge
Quantity
 ≤ 20pC( Standard configuration≤ 10pCOptional features≤ 5pCOptional features
Device Efficiency ≥ 90%
Overload Capacity 120%-150%, 1 minute; 150%-200%, 2 seconds; 200%, immediate output shutdown.
System Function  
Online Adjustment
Function
Output voltage and frequency can be adjusted online.
Quick Settings
Function
Multiple output voltages and frequencies can be customized.
Memory FunctionAfter a power outage and subsequent power restoration, the device can remember the last output mode and parameters.
Protection FunctionInput undervoltage/overvoltage and phase loss protection, output overvoltage, overcurrent, overload, and short-circuit protection, and
internal overtemperature protection, etc.
Display and Communication
Local Operation LCD display screen
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote Communication RS 485/LAN
Communication protocol Standard Modbus RTU/Modbus TCP/IP
Safety Performance  
Compressive Strength 2000 Vdc / 60 seconds / No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment  
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling MethodFan-forced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000m Reduced usage
Power supply
(W*D*H)mm
520*1160*1360
(With wheels)
650*1420*1470
(With wheels)
1550*850*1985
(With wheels)
1550*850*1985
(With wheels)
1900*1100*1970
FilterW*D*H
mm
1000*572*1621000*572*1621300*700*2601300*700*2601300*700*260

 

    800*500*162      800*500*162

Unit TypeWF60-33100WF60-33200WF60-33300WF60-33450WF60-33600WF60-33900
Rated Power10kVA20kVA30kVA45kVA60kVA90kVA
Input AC Indicators     
Power Supply FormatThree-phase four-wire + PE (protective earth)
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply FormatThree-phase four-wire
Voltage Range0~800VL-L( Standard configuration/0~1000VL-L(Optional features
Current Range7A14A21A32A42A63A
Frequency RangeFixed frequency: 50/60Hz, Variable frequency: 30~300Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonic≤ 2%
Response Time≤ 5ms
Partial Discharge
Quantity
20 pC (standard) / 10 pC (optional) / 5 pC (optional)
Device Efficiency≥ 90%
Overload Capacity     120%–150%, 1 minute; 150%–200%, 2 seconds; 200%, immediate output shutdown.
System Function 
Online Adjustment
Function
Output voltage and frequency can be adjusted online.
Quick Settings
Function
Multiple output voltages and frequencies can be customized.
Memory Function    After a power outage and subsequent power restoration, the device can remember the last output mode and parameters.
Protection FunctionInput undervoltage/overvoltage and phase loss protection, output overvoltage, overcurrent, overload, and short-circuit
protection, and internal overtemperature protection, etc.
Display and Communication
Local Operation LCD display screen
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote Communication RS 485/LAN
Communication protocol Standard Modbus RTU/Modbus TCP/IP
Safety Performance
Compressive Strength 2000 Vdc / 60 seconds / No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling MethodFan-forced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Power supply
(W*D*H)mm
500*820*1100
(With wheels)
500*820*1100
    (With wheels)
     520*1160*1360
       (With wheels)
520*1160*1360
(With wheels)
650*1420*1470
(With wheels)
650*1420*1470
(With wheels)
FilterW*D*H
mm
800*500*162800*500*1621000*600*1621000*600*162

 

Unit TypeWF60-331000WF60-331200WF60-331500WF60-332000WF60-333000WF60-334000
Rated Power100kVA120kVA150kVA200kVA300kVA400kVA
Input AC Indicators      
Power Supply FormatThree-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply Format Three-phase four-wire
Voltage Range 0~800VL-L( Standard configuration)/0~1000VL-LOptional features
Current Range      72A86A108A144A216A288A
Frequency Range Fixed frequency: 50/60Hz, Variable frequency: 30~300Hz
Source Effect ≤ 0.1%F.S
Load Effect ≤ 0.1%F.S
Voltage Accuracy ≤ 0.1%F.S
Frequency Accuracy ≤ 0.01%F.S
Voltage Harmonic ≤ 2%
Response Time ≤ 5ms
Partial Discharge
Quantity
 ≤ 20pC(Standard configuration)/ ≤ 10pC(Optional features)/ ≤ 5pC(Optional features
Device Efficiency ≥ 90%
Overload Capacity 120%~150% , 1min; 150%~200% 2s ;≥ 200% , Immediately shut off the output.
System Function  
Online Adjustment
Function
Output voltage and frequency can be adjusted online.
Quick Settings
Function
Multiple output voltages and frequencies can be customized.
Memory FunctionAfter a power outage and subsequent restoration, the device can remember the last output mode and parameters.
Protection Function   Input undervoltage and overvoltage protection, phase loss protection; output overvoltage, overcurrent, overload, and short-circuit
   protection; internal overtemperature protection, etc.
Display and Communication
Local Operation LCD display
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S., Current: 0.2% F.S., Frequency: 0.01%, Power: 0.3% F.S.
Remote Communication RS 485/LAN
Communication Protocol Standard Modbus RTU/Modbus TCP/IP
Safety Performance  
Compressive Strength 2000 Vdc / 60 seconds / No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment  
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures of -20℃ to 45℃ and relative humidity of 0 to 95%.
Cooling MethodFan-forced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Power supply
(W*D*H)mm
650*1420*1470
(With wheels)
650*1420*1470
(With wheels)
650*1420*1470
(With wheels)
1550*850*1985
(With wheels)
1550*850*1985
(With wheels)
1900*1100*1970
FilterW*D*H
mm
1000*600*1621000*600*1621000*600*1621300*770*2601300*770*2601300*770*260

 

Series Partial Discharge-free Power Supply
Waveform Purity: Low harmonic distortion

Overload Robust: Modular design, impact resistant, zero voltage drop

Fast Dynamic Response: Small voltage drop, fast recovery

Intuitive Operation: LCD touchscreen

Stable Frequency: Quartz oscillator, high precision

Strong Anti-interference: Fiber optic drive, high reliability

Comprehensive Protection: Electrostatic powder coating, conformal coating +
Long press to look detail
Long by picture save/share
Add Successfully

Series Partial Discharge-free Power Supply

enquiry
Add Successfully

Contact Us

Send your message to this supplier

  • First Name

  • Last Name

  • Email

Subscribe

Security Code
Refresh the code
Cancel
Confirm

MAIN MENU

About   |   Products   |   News     Cases

Contact

Copyright © Hebei Power Link Electric Equipment Technology Co., LTD All Rights Reserved

Service Center

Please choose online customer service to communicate

Contacts
E-mail
info@powerlinkelectric.com
Mobile/WhatsApp/Wechat
+8615531143445
Scan a QR Code
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.